An Isothermal Microcalorimeter with Integrated CO2 Sensor for Simultaneous Measurement of Microbial Heat Evolution and Mineralization

14 March 2025, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Soil, as the largest terrestrial carbon sink, plays a crucial role in carbon sequestration. Within soil systems, microorganisms decompose soil organic matter to generate energy and obtain carbon for growth, concomitantly release heat and CO2 as metabolic byproducts. The calorespirometric (CR) ratio – defined as the ratio of heat production to CO2 evolution, is a key indicator of carbon use efficiency and soil anaerobicity. However, conventional methodologies typically measure heat and CO2 separately, with CO2 often quantified by intermittent sampling. This discontinuous approach, compounded by the inherent heterogeneity of soil, introduces uncertainties in calorespirometric analysis. To address this limitation, an infrared CO2 sensor was mounted onto a stainless-steel calorimetric ampoule, containing soil-glucose mixtures, enabling simultaneous real-time measurements within an isothermal microcalorimeter. The novel configuration permits continuous monitoring of both parameters, validated through comparative analysis with traditional methods. The derived CR ratio aligned with theoretical predictions for carbohydrates metabolism. Furthermore, parallel oxygen measurements enabled quantification of CR ratio based on O2 (heat-to-O2), and the respiratory quotient (CO2-to-O2)), offering deeper insight into microbial carbon-energy coupling and turnover in soil systems. This methodological advancement enhances the capacity to interrogate soil biogeochemical processes under dynamic environmental conditions.

Keywords

Calorimtry
Respirometry
Calorespirometric Ratio
Soil
CO2 sensor

Supplementary materials

Title
Description
Actions
Title
An Integrated Measurement of Microbial Heat and CO2 Evolution (Calorespirometric Ratio) in Soil Using an Established Isothermal Microcalorimeter Coupled with a CO2 Sensor
Description
Collected Supplementary Material
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.