Using retention index database matching for compound identification on a non-standard gas chromatography stationary phase

04 September 2024, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

In gas chromatography (GC), the retention index (RI) system was developed to compare the retention times of volatilizable compounds across GC systems and to RI databases to aid in compound identification. The mid-polar 624 GC stationary phase (6% cyanopropylphenyl/94% dimethylpolysiloxane) is becoming a common choice for bioanalysis and metabolomics. However, referenceable RI data for compounds separated on the 624 stationary phase are limited, hindering the ability to identify unknowns. Comparing 624 retention indices for 252 compounds to their corresponding nonpolar and polar retention indices in the National Institute of Standards and Technology (NIST) GC RI database, we identified a strong linear relationship (R2 = 0.99) between the 624 and nonpolar values and an equation to interconvert between them. Thus, retention indices obtained on a 624 stationary phase can now be compared to the NIST GC RI database; however, there are no standardized criteria for determining whether an observed RI and a database RI value are a match. To develop RI match criteria, we evaluated the variability of the RI values in NIST for each of the 252 compounds in this study. Based on our findings, we suggest defining an observed nonpolar RI that is within one standard deviation of the median value in NIST as a strong match (i.e., within 12 units for a nonpolar RI match or 14 units for a polar RI match), and defining a weak match using looser criteria, e.g., within three standard deviations of the median RI value in NIST. Lastly, we provide an example for how to use strong and weak RI matches as part of the workflow for compound identification in a gas chromatography – mass spectrometry analysis, with the goal of assigning Metabolomics Standards Initiative confidence levels to each identification.

Keywords

gas chromatography
retention indexing
624 stationary phase
metabolomics standards initiative
NIST database

Supplementary materials

Title
Description
Actions
Title
Supplementary Information
Description
Supplementary methods, including the chemical standards mixes used in the study; all chromatographic and mass spectrometric methods; R script for scraping retention indices from NIST Chemistry Webbook. Supplementary results, including Supplementary Figure 1
Actions
Title
Supplementary Excel File (Table S6)
Description
Supplementary Table 6: Retention index data for 252 compounds collected on 624, nonpolar, and polar stationary phases.
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.