Variable-Area Sensor Permits Near-Continuous Multi-Point Measurements of Aqueous Biological and Chemical Analytes

25 July 2024, Version 2

Abstract

The timely detection of aqueous analytes is critical to decision-makers in agriculture, industry, and munici-palities. However, nearly all water sensor systems rely on single-point measurements, often taken at an instantaneous point in time and in one location, which can limit their ability to detect analytes passing through the water matrix at other locations or times. In this work, we present the concept of employing a mass-manufactured nanotextured diffraction surface as a variable-area sensor system capable of provid-ing spectrophotometric information on aqueous analytes across multiple locations over time. We show that by placing the nanotextured surface of the sensor system under or behind a water matrix, the water can be scanned by simply changing the location or angle of the light source and detector. We demonstrate the detection and quantification of a variety of aqueous analytes, including visible and ultraviolet (UV)-absorbing dyes, dust particles, and microalgae species at accuracies similar to commercial spectropho-tometers. A machine learning algorithm was used to lower the limit of detection of methylene blue from 5 µg/mL to 3 µg/mL and automate the classification of three distinct analyte types. These results demonstrate that using a mass-produced, textured surface as a sensor can offer benefits in water sensing capabilities, facilitating widely deployable aqueous analyte monitoring in a variety of applications.

Keywords

bacteria
detection
microalgae
pollutants
water sensor

Supplementary materials

Title
Description
Actions
Title
Supporting Information
Description
Biological sample preparation, microalgae microscopy, refractive index calculation, refractive index, calculated absorbance of dyes, Rhodomonas sp. microscopy images, diffraction sensor results of microalgae species, and measured UV-Vis spectra of nickel sulfate.
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.
Comment number 1, Liza White: Nov 26, 2024, 20:50

A more recent article was published on ACS Industrial & Chemistry Research. The article can be found: https://pubs.acs.org/doi/abs/10.1021/acs.iecr.4c02774?mi=6gv8cuj&af=R&AllField=electrochemical+sensors&PubType=journals&target=default&targetTab=std