MobiLipid: A Tool for Enhancing CCS Quality Control of Ion Mobility-Mass Spectrometry Lipidomics by Internal Standardization

26 March 2024, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Ion mobility-mass spectrometry (IM-MS) offers benefits for lipidomics by obtaining IM-derived collision cross sections (CCS), a conditional physicochemical parameter of an ion which can enhance lipid identification. While drift tube (DT) IM-MS retains a direct link to the primary experimental method to derive CCS values, other IM technologies rely solely on external CCS calibration, posing challenges due to dissimilar chemical properties between lipids and calibrants. To address this, we introduce MobiLipid, a novel tool facilitating CCS quality control of IM-MS lipidomics workflows by internal standardization. MobiLipid utilizes a newly established DTCCSN2 library for uniformly (U)13C labeled lipids, derived from a U13C labeled yeast extract, containing 377 DTCCSN2 values. This automated open-source R markdown tool enables internal monitoring and straightforward compensation for CCSN2 biases. It supports lipid class- and adduct-specific CCS corrections, requiring only three U13C labeled lipids per lipid class-adduct combination across 10 lipid classes, without requiring additional external measurements. The applicability of MobiLipid is demonstrated for trapped IM (TIM)-MS measurements of an unlabeled yeast extract spiked with U13C labeled lipids. Monitoring the CCSN2 biases of TIMCCSN2 values compared to DTCCSN2 library entries utilizing MobiLipid resulted in mean absolute biases of 0.78% and 0.33% in positive and negative ionization mode, respectively. By applying the CCS correction integrated into the tool for the exemplary dataset, the mean absolute CCSN2 biases of 10 lipid classes could be reduced to approximately 0%.

Keywords

Lipidomics
Ion mobility-mass spectrometry
CCS quality control
Stable isotope-labeled biomass
Internal standardization
CCS correction

Supplementary materials

Title
Description
Actions
Title
Supplementary Experimental Section & Figures
Description
Supplementary Experimental Section including detailed sample preparation workflow, LC-IM-MS measurement parameters, settings for data processing, and CCS bias calculation; Supplementary Figures including equivalent carbon number model for CCS values, CCS bias before and after CCS correction using MobiLipid, CCS bias for distinct correction functions, CCS bias dependent on modified CCS, and CCS bias between unlabeled and U13C labeled lipids.
Actions
Title
Supplementary Tables
Description
Supplementary Tables including DTCCSN2 library for U13C la-beled lipids, exemplary output tables of MobiLipid, and results for LC-DTIM-MS and LC-TIM-MS measurements.
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.