Point Sensor Networks Struggle to Detect and Quantify Short Controlled Releases at Oil and Gas Sites

20 February 2024, Version 3
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

This study evaluated multiple commercially available continuous monitoring (CM) point sensor network (PSN) solutions under single-blind controlled release testing conducted at operational upstream and midstream oil and natural gas (O&G) sites. During releases, PSNs reported site-level emission rate estimates of 0 kg/h between 38-86% of the time. When non-zero site-level emission rate estimates were provided, no linear correlation between release rate and reported emission rate estimate was observed. The average, aggregated across all PSN solutions during releases, shows 5% of mixing ratio readings at downwind sensors were greater than the site's baseline plus two standard deviations. Four of six total PSN solutions tested during this field campaign provided site-level emission rate estimates with the site average relative error ranging from -100% to 24% for solution D, -100% to -43% for solution E, -25% for solution F (solution F was only at one site), and -99% to 430% for solution G, with an overall average of -29% across all sites and solutions. Of all the individual site-level emission rate estimates, only 11% were within +/- 2.5 kg/h of the study team's best estimate of site-level emissions at the time of the releases.

Keywords

Methane
emissions abatement
continuous monitoring
emissions quantification
oil and gas
GHG
Green House Gas

Supplementary materials

Title
Description
Actions
Title
Point Sensor Networks Struggle to Detect and Quantify Short Controlled Releases at Oil and Gas Sites - Supplementary Information
Description
The document contains relevant additional and supplementary information that was not captured nor discussed in the main paper.
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.