Discerning ambiguous internal fragment assignments that are generated in top-down mass spectrometry with cyclic ion-mobility enhances protein sequence information

21 December 2023, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Top-down mass spectrometry (TD-MS) has become a central technique for the analysis of intact proteins, and internal fragments (fragments containing neither the C- nor N-terminus) have been utilized to enhance the sequence information extracted from such experiments. A key obstacle to including internal fragments in TD-MS workflows stems from potential ambiguities in their assignments, which can severely impact the confidence of assignments and increase false discovery. To utilize internal fragments in TD-MS precisely, it is therefore crucial to discern ambiguous internal fragment assignments. Here, we demonstrate that by including ion mobility, ambiguous internal fragments can be discerned to enable more confident assignments. For example, the β-Casein-derived internal fragments a115¬-x132 and a114¬-x131 were both assigned to 1000.51 m/z; however, ion mobility of this m/z showed two different arrival time distributions: 25.5 ms and 30.0 ms. The different theoretical volumes of a115¬-x132 and a114¬-x131 – 680.6 and 682.3 respectively – enabled their assignments to the respective 25.5 ms and 30.0 ms arrival times. For the test proteins myoglobin, carbonic anhydrase II, β-Casein, and bovine serum albumin, the inclusion of ion mobility discerned internal fragments increased sequence coverage from <55% to >85%, which is near complete sequence coverage for these proteins. By applying this method to a protein complex, trustuzamab, the sequence coverage and sequence information returned for both the heavy and light chains were 85% and 90% respectively. These data demonstrate that the inclusion of ion mobility in TD-MS experiments can enhance the confidence of internal fragment assignments, and significantly extend protein sequence information relative to TD-MS experiments that do not incorporate ion mobility.

Keywords

Top-down MS
Ion mobility
Proteoform characterisation

Supplementary materials

Title
Description
Actions
Title
Supplementary Information for Discerning ambiguous internal fragment assignments that are generated in top-down mass spectrometry with cyclic ion-mobility enhances protein sequence information
Description
Supplementary Information for Discerning ambiguous internal fragment assignments that are generated in top-down mass spectrometry with cyclic ion-mobility enhances protein sequence information
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.