Abstract

Membrane transport properties are crucial for electrochemical devices, and these properties are influenced by the composition and concentration of the electrolyte in contact with the membrane. We apply this general membrane-electrolyte system approach to alkaline flow batteries, studying conductivity and ferricyanide crossover of Nafion and E-620. We report undetectable crossover for as-received Nafion and E-620 after both sodium and potassium exchange, but high ferricyanide permeability of 10^−7 to 10^−8 cm^2 s^−1 for Nafion subjected to pre-treatment prevalent in the flow battery literature. We show how the electrolyte mass fraction in hydrated membranes regulates the influence of ion concentration on membrane conductivity, identifying that increasing electrolyte concentration may not increase membrane conductivity even when it increases electrolyte conductivity. To illustrate this behavior we introduce a new metric, the membrane penalty, as the ratio of the conductivity of the electrolyte to that of the membrane equilibrated with the electrolyte. We discuss the tradeoff between flow battery volumetric capacity and areal power density that arises from these findings. Finally, we apply insights from this approach to provide recommendations for use of membranes in alkaline flow cells, and electrochemical reactors in general.

Keywords

ion exchange membrane
redox flow battery
selectivity
equilibrium

Supplementary materials

Title
Description
Actions
Title
Supplementary Material
Description
The supplementary material contains photographs of the experimental setups, additional data for determining permeability including UV-vis spectra, additional conductivity ad electrolyte mass fraction data, and tabulated results.
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.