Comprehensive analysis of relaxation decays from high-resolution relaxometry

21 August 2023, Version 2
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Relaxometry consists in measuring relaxation rates over orders of magnitude of magnetic fields to probe motions of complex systems. High-resolution relaxometry (HRR) experiments can be performed on conventional high-field NMR magnets equipped with a sample shuttle. During the experiment, the sample shuttle transfers the sample between the high-field magnetic center and a chosen position in the stray field for relaxation during a variable delay, thus using the stray field as a variable field. As the relaxation delay occurs outside of the probe, HRR experiments cannot rely on the control of cross-relaxation pathways, which is standard in high-field relaxation pulse sequences. Thus, decay rates are not pure relaxation rates, which may impair a reliable description of the dynamics. Previously, we took into account cross-relaxation effects in the analysis of high- resolution relaxometry data by applying a correction factor to relaxometry decay rates in order to estimate relaxation rates. These correction factors were obtained from the iterative simulation of the relaxation decay while the sample lies outside of the probe and a preceding analysis of relaxation rates which relies on the approximation of a priori multi-exponential decays by mono-exponential functions. However, an analysis protocol matching directly experimental and simulated relaxometry decays should be more self consistent. Here, we introduce Matching INtensities for the Optimization of Timescales and Amplitudes of motions Under Relaxometry (MINOTAUR), a framework for the analysis of high-resolution relaxometry that takes as input the intensity decays at all fields. This approach uses the full relaxation matrix to calculate intensity decays, allowing complex relaxation pathways to be taken into account. Therefore, it eliminates the need for a correction of decay rates and for fitting multi-exponential decays with mono-exponential functions. The MINOTAUR software is designed as a flexible framework where relaxation matrices and spectral density functions corresponding to various models of motions can be defined on a case-by-case basis. The agreement with our previous analyses of protein side-chain dynamics from carbon-13 relaxation is excellent, while providing a more robust analysis tool. We expect MINOTAUR to become the tool of choice for the analysis of high-resolution relaxometry.

Keywords

Nuclear Magnetic Resonance
NMR Relaxation
Protein Dynamics
Relaxometry

Supplementary materials

Title
Description
Actions
Title
Supporting Materials
Description
Additional tables and figures. Expressions of relaxation rates used in this work. Protocol on how to use MINOTAUR.
Actions

Supplementary weblinks

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.