Optimized design and protocols eliminate power density gap between microbial fuel cells at different scales

21 April 2023, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

In addition to offering a promising approach for niche applications in environmental sensing and portable power sources, microfluidic microbial fuel cells (MFCs) can also accelerate the development of mainstream energy applications through studies into fundamental mechanisms and optimization, without complications from nutrient cycling, membrane fouling, or uncontrollable concentration gradients. However, the main hurdle in leveraging microfluidic MFCs for discovery and optimization is their underperformance compared to macrosystems on certain key metrics, notably area-normalized power. To bridge this gap, we showcase a strategy that focuses on (i) technology improvements, (ii) establishment of new performance benchmarks, and (iii) presentation of a universally applicable normalization method for direct comparisons across all MFC scales and that complements areal power densities. Using a pure-culture Geobacter sulfurreducens electroactive biofilm (EAB) applied to a new system that adheres to the strategy above, we observed optimal anode colonization, resulting in the highest recorded power density for a microfluidic MFC of 3.88 W m-2 (24.37 kW m-3) and a normalized energy recovery (0.21 kWh m-3) that nearly matches the average value observed in macrosystems. With these results, the performance gap between micro- and macroscale MFCs is closed, and a road map to move forward is presented.

Keywords

Membraneless microbial fuel cells
Power density
Energy recovery
Geobacter sulfurreducens
Microfluidics
Normalization

Supplementary materials

Title
Description
Actions
Title
Optimized design and protocols eliminate power density gap between microbial fuel cells at different scales
Description
Advantage of using continuous bubble-free liquid delivery system explained with a voltage versus time profile for a microfluidic MFC with (blue) and without (orange) pressure-drop channels and continuous, bubble-free liquid delivery using four-way valves.
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.