Evaluation of Data Dependent MS/MS Acquisition Parameters for Non-targeted Metabolomics and Molecular Networking of Environmental Samples - Focus on the Q Exactive Platform

20 March 2023, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Non-targeted liquid chromatography tandem mass spectrometry (LC-MS/MS) is a widely used tool for the detection and annotation of small molecules in complex environmental samples. Data Dependent Acquisition (DDA) of product ion spectra is thereby currently one of the most frequently applied data acquisition strategies. The optimization of DDA parameters is central to ensuring high spectral quality, coverage and number of compound annotations. Here, we evaluated the influence of 10 central DDA settings of the Q Exactive mass spectrometer on natural organic matter samples from ocean, river, and soil environments. After data analysis with Classical and Feature-based Molecular Networking using MZmine and GNPS, we compared the total number of network nodes, multivariate clustering, and spectrum quality related metrics such as annotation and singleton rates, MS/MS placement and coverage. Our results show that Automatic Gain Control, Microscans, Mass Resolution, and Dynamic Exclusion are the most critical parameters, whereas Collision Energy, TopN, and Isolation Width had moderate and Apex Trigger, Monoisotopic Selection, and Isotopic Exclusion minor effects. The insights into the data acquisition ergonomics of the Orbitrap platform presented here can guide new users and provide them with initial method parameters, some of which may also be transferable to other sample types and MS platforms.

Keywords

Environmental Metabolomics
Natural Organic Matter
Tandem Mass Spectrometry
Orbitrap
Molecular Networking

Supplementary materials

Title
Description
Actions
Title
Supporting Information: Evaluation of Data Dependent MS/MS Acquisition Parameters for Non-targeted Metabolomics and Molecular Networking of Environmental Samples - Focus on the Q Exactive Platform
Description
Supplemental Methods, tables and Figures
Actions

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.