An Intelligent AIEgen with Nonmonotonic Multi-Responses to Multi-Stimuli

20 February 2020, Version 2
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Intelligent stimulus-response (S/R) systems are the basis of natural process and machine control, and have been intensively explored in biomimetic design, analytical chemistry and biological applications. However, nonmonotonic multi-S/R systems are still rarely studied so far. Now, we propose a rational design strategy to achieve such a unique S/R system by integrating opposite luminescence behaviors in one molecule. When solvent polarity increases, many heterocycles often become more emissive due to the suppression of the proximity effect. However, molecules with donor-acceptor (D-A) structures tend to be less emissive because of the twisted intramolecular charge transfer. Meanwhile, protonation on D/A moieties will weaken/strengthen the D-A interaction to result in blue/red-shifted emissions. By combining a protonatable heterocyclic acceptor and a protonatable donor together in one molecule, we can easily achieve nonmonotonic brightness responses to polarity stimuli and nonmonotonic color responses to pH stimuli. In this work, a simple molecule, namely ASQ is chosen as the model compound to verify the design strategy feasibility. It successfully shows two opposite trends of responses to polarity and pH stimuli, and aggregation-induced emission (AIE) with a nonmonotonic AIE curve. Moreover, the acidified ASQ solution is also a pure organic up-conversion and white-light-emitting system. A new mechanistic viewpoint is established to explain its unique anti-Stokes emission. Besides, ASQ shows multivalent functionalities including albumin protein sensing, ratiometric pH sensing, and amine gas sensing, etc. Therefore, ASQ is proved to be a fundamentally important and versatile functional “intelligent” AIE luminogen with nonmonotonic multi-responses to multi-stimuli.

Keywords

Nonmonotonic fluorescence response
Aggregation-induced emission
Up-conversion
White-light emission
Albumin sensor
Amine gas sensor

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.