A General Approach to Combine the Advantages of Collinear and Non-Collinear Spectrometer Designs in Phase-Resolved Second Order Nonlinear Spectroscopy

25 November 2019, Version 1
This content is a preprint and has not undergone peer review at the time of posting.

Abstract

Recent years have seen a huge progress in the development of phase sensitive second order laser spectroscopy which has proven to be a very powerful tool for the investigation of interfaces. These interferometric techniques involve the nonlinear interaction between three short laser pulses with the sample. In order to obtain accurate phase information, the relative phases between the pulses must be stabilized and their timings precisely controlled. Despite much progress made, fulfilling both requirements remains a formidable experimental challenge. The two common approaches employ different beam geometries which each yields its particular advantages and deficiencies. While non-collinear spectrometers allow for a relatively simple timing control they typically yield poor phase stability and require a challenging alignment. Collinear approaches in contrast come with a simplified alignment and improved phase stability but typically suffer from a highly limited timing control. In this contribution we present a general experimental solution which allows for combining the advantages of both approaches while being compatible with most of the common spectrometer types. Based on a collinear geometry we exploit different selected polarization states of the light pulses in well- defined places in the spectrometer to achieve a precise timing control. The combination of this technique with a balanced detection scheme al- lows for the acquisition of highly accurate phase resolved nonlinear spectra without any loss in experimental flexibility. In fact, we show that the implementation of this technique allows us to employ advanced pulse timing schemes inside the spectrometer, which can be used to sup- press nonlinear background signals and extend the capabilities of our spectrometer to measure phase resolved sum frequency spectra of inter- faces in a liquid cell.

Keywords

sum frequency generation spectrometer
sum Frequency Generation Vibrational Spectroscopy
collinear
balanced detection
time domain
Heterodyne

Comments

Comments are not moderated before they are posted, but they can be removed by the site moderators if they are found to be in contravention of our Commenting Policy [opens in a new tab] - please read this policy before you post. Comments should be used for scholarly discussion of the content in question. You can find more information about how to use the commenting feature here [opens in a new tab] .
This site is protected by reCAPTCHA and the Google Privacy Policy [opens in a new tab] and Terms of Service [opens in a new tab] apply.